Owner manual
49
6.6.2 Technical data of RFI filters
f
e
d
a
c
b
g
c
g
b
e
d
a
f
Design A Design B
Filter type Order number a b c d e f g m Weight
Design Rt. current mm mm mm mm mm mm mm mm kg
A 8.0A EZF3-008A001 220 115 100 180 60 17 115 6.5 1.8
A 16.0A EZF3-016A001 240 150 135 200 65 17 115 6.5 1.8
A 25.0A EZF3-025A001 250 150 135 200 65 17 115 6.5 3.0
A 36.0A EZF3-036A001 250 150 135 200 65 17 115 6.5 3.0
A 50.0A EZF3-050A004 250 150 135 200 65 17 115 6.5 3.1
B 80.0A EZF3-080A001 427 170 130 350 90 70 375 15.0 9.5
B 110.0A EZF3-110A001 436 170 130 350 90 70 375 15.0 9.5
B 180.0A EZF3-180A001 537 180 156 350 152 88 470 16.0 13.0
6.7 Accessories for digital frequency networking
• System cable for master-slave connection between the
individual controllers
• Second digital frequency input (SubD-plug X8),
including assembly kit
• Digital frequency output (SubD-socket X9),
including assembly kit
• Adapter for incremental encoder
The adapter is required when the incremental encoder is to be
connected to the inverter via terminals - X5 or X8.
Name Order no.
System cable (2.5 m long) EWLD002GGBB92
X8 9-pole SubD-plug (2nd digital frequency input) EWZ0008
X9 9-pole SubD-socket (digital frequency output) EWZ0009
Adapter for incremental encoder (terminal/SubD-plug) EWZ00011