Assignment of the digital inputs
The number of required inputs for the function "Enable JOG
frequency" depends on the amount of the required JOG
frequencies.
JOG frequencies
Number of required JOG
frequencies
Number of required inputs
1 at least 1
2...3 at least 2
4...7 at least 3
8...15 4
A maximum of four inputs can be assigned to this function. For the
assignment of the inputs see the notes on page 78.
Enabling JOG frequencies
With terminal control activate the assigned digital inputs
according to the table below.
The input with the smallest number is the first input, the input with
the next highest number is the second input, etc.
(e.g. E4 = first input, E5 = second input).
1st input 2nd input 3rd input 4th input
JOG 1 1 0 0 0
JOG 2 0 1 0 0
JOG 3 1 1 0 0
JOG 4 0 0 1 0
JOG 5 1 0 1 0
JOG 6 0 1 1 0
JOG 7 1 1 1 0
JOG 8 0 0 0 1
JOG 9 1 0 0 1
JOG 100101
JOG 111101
JOG 120011
JOG 131011
JOG 140111
JOG 151111
With terminal control, the active JOG frequency is displayed under
C045.
With control via keypad or LECOM interfaces C045 is used to
activate the JOG frequencies.
Code Parameter Meaning Acceptance
C045 -0-
-1-
-2-
-...-
-15-
Activate set-value 1
Activate JOG 1
Activate JOG 2
Activate JOG ...
Activate JOG 15
SH + PRG