Owner manual
83
Enabling the additional acceleration and deceleration times
With terminal control activate the assigned digital inputs
according to the table below.
The input with the smallest number is the first input, the input with
the next highest number is the second input, etc.
(e.g. E7 = first input, E8 = second input).
1st input 2nd input 3rd input 4th input
T
ir
1, T
if
11 0 0 0
T
ir
2, T
if
20 1 0 0
T
ir
3, T
if
31 1 0 0
T
ir
4, T
if
40 0 1 0
T
ir
5, T
if
51 0 1 0
T
ir
6, T
if
60 1 1 0
T
ir
7, T
if
71 1 1 0
T
ir
8, T
if
80 0 0 1
T
ir
9, T
if
91 0 0 1
T
ir
10, T
if
100101
T
ir
11, T
if
111101
T
ir
12, T
if
120011
T
ir
13, T
if
131011
T
ir
14, T
if
140111
T
ir
15, T
if
151111
C130 displays the active pair of ramp times.
With control via keypad or LECOM interfaces C130 is used to
activate a pair of ramp times.
Code Parameter Meaning Acceptance
C130 -0-
-1-
-2-
-...-
-15-
Activate standard pair of ramp times
Activate pair of ramp times 1
Activate pair of ramp times 2
Activate pair of ramp times ...
Activate pair of ramp times 15
SH + PRG