Technical data
2.1
General data
Mains voltage:
Output voltage:
Output frequency:
Chopper frequency:
Threshold of the integrated brake
chopper
Enclosure:
Ambient temperature:
Noise
immun@
Permissible
pollution
3 x
46OV
AC, 45 to 65 Hz
Permissible voltage range:
330...526
V
(as alternative:
470...740\1
DC
supply)
3 X 0
t0
Vmains
(V
-
fd with 400V at
50Hz,
adjustable, mains-independent)
When using a mains
Choke,
the maximum possible output voltage is
reduced to approx. 96% of the mains voltage.
0 to
50Hz,
adjustable
up
to
480Hz
4kHz factory
setting,
adjustable from 2 to
16kHz
765 V DC in the DC bus
Steel-sheet
housing,
IP20
to DIN 40050
0 to 50°C during Operation
(for rating see page 19)
-25 to 55°C
during
storage
-25 to 70°C
during
transport
Severity
class
4 to IEC 801-4
Pollution level
l 2 to VDE 0110,
part
2. The
controller
should not be exposed to
corrosive
or explosive
gases.
permissible
Influence of installation altitude on 1000 m: 100% rated
current
the rated
current:
2000 m: 95% rated
current
3000 m: 90% rated
current
4000 m: 65% rated
current
lmze