User Manual

12.3.5 Baud rate (LECOMI)
Under
code
Cl
25 you
tan
enter different baud
rates.
Code
Cl25
Parameter
Meaning
4% 9600
baud
-l-
4800 baud
-2-
2400 baud
-3-
1200 baud
12.3.6 History of reset faults
Under
Cl 61 to
Cl
68 you
tan
read the last eight faults stored. The
last reset fault is displayed in Cl 61.
12.3.7 Code bank (LECOMI)
With
version
1 .O of the LECOM
A/B
protocol,
Codes
up to C255
tan
be processed. To
resch
also
higher
numbers with this Version, the
accessible range
tan
be
changed
by
code
C249. Code C249 exists
in every range.
Parameter In C249 Access to
code
range
-O-
cooo...c255
-l-
C25O...C505
-2- c5oo...c755
-3-
c750...c1005
-4
C1000...1255
-5- C125O...C1505
-6-
c15oo...c1755
-7-
C175O...C2000
Further
information
about
serial communication with the
Standard
interface
LECOMl
(LECOM-AIB),
tan
be obtained from the
technical description LECOM-A/B,
which
we will be pleased to send
you on request.
12.3.8 Enable automation interface (LECOM2)
If you want to integrate the controller into
complex
automation
Systems,
you
tan
connect an interface,
e.g.
Interbus-S or Profibus
or an automation module.
Install
the module and activate it
under
c370.
Code 1 Parameter
)
Meaning
c370
4%
-l-
No communication via automation interface
(LECOM2)
Communication via automation inteface (LECOM2)
ena
hkx-l
If the communication via
C370
is enabled but an automation
module is not connected, the controller is inhibited.
142