User Manual

-.
5.2.3
DGinjection
brake
If
you want to brake the drive fast, but do not want to use a brake
chopper,
you
tan
activate the DC-injection brake via the
suitable
input. Please note that the braking time may vary
each
time.
Before you
tan
use the
DGinjection
brake, set the brake voltage
under
C036. The brake voltage also determines the brake current
and therefore the brake torque.
If
the current limitation is activated
by the brake current, reduce the brake voltage.
To limit the time of the
DC-injection
brake, you
tan
program
a
holding time
under
C107.
After the holding time has elapsed, the
controller
switches the output voltage to
Zero.
With a holding time
of 999s the braking time is unlimited.
Extended Operation of the
IX-injection
brake may
Cause
the motor
to overheat!
Code
CO36 Voltage for 0%
1
Name Parameter (Factory setting is printed in bold) Acceptance
0 %
(0.1
%)
40%
ON.LINE
DC-injection
brake
Cl07
Holding time
999 s 0.00 s (10 ms) 1
.OO
s ON-LINE
for
DC-
1.0s (100 ms) 10.0s
injection brake
10s
11
SI
100s
100s
1101
999 s
INFO: 999 s = Unlimited holding time
With ,terminal control CO48 serves as display whether the
DC-
injection brake is
active
or not.
With control via the keypad or the
LECOM
interfaces
the
DC-
injection brake is (de-)activated via C048.
Code
t
Name Parameter (Factory setting is printed in bold)
Co48
Enable
DC-
-o-
DC-injection brake
inhibited/deactivate
injection brake
-q-
DC-injection brake
enabled/activate
For information
about
the
automatic
DC injection brake see
page 97.
Acceptance
SH
+
PRG
bue
83