Owner manual
Parameter setting
Loading and saving of parameter sets
Description of the objects
7
l 71
KHB 13.0002−EN 4.1
7.1.2 Description of the objects
Index Name Possible settings
Characteristics
Lenze Selection Description
1010
h
0 store_parameters
ARR UINT8 RO
Not used.
1 save_all_
parameters
00000001
h
00000000
h
{1
h
} 65766173
h
UINT32 RW
Acceptance of default
parameter set in application
parameter set.
00000000
h
Default parameter set is not
accepted.
65766173
h
Save Default parameter set is
accepted.
1011
h
0 restore_parameters
ARR UINT8 RO
Query on the number of
possible objects.
1 restore_all_default
_parameters
00000001
h
00000000
h
{1
h
} 64616F6C
h
UINT32 RW
Loading of the default
parameter set, only possible
if the power stage is
deactivated.
The CAN communication
parameters (node no., baud
rate and operating mode)
remain unchanged.
64616F6C
h
Load Loading of default parameter
set.
00000001
h
Read access: Reset to default
values.