Owner's manual

Table Of Contents
Appendix
Index table
10
123
KHB 13.0003-EN 2.0
Characteristics
Possible settingsNameIndex
DescriptionSelectionLenze
1016
h
Consumer_
heartbeat_time
0 number_of_entries
01
h
{1
h
} 7F
h
VAR UINT8 RO
Maximally supported
subindices.
01
h
1 subindex is supported.
1 consumer_
heartbeat_time
0 {1 ms} 65535
VAR UINT3
2
RW
Setting the time in which
the controller expects a
message from the master.
Thetimemustbelonger
than the corresponding
index
producer_heartbeat_time.
”0” means that the
function is deactivated.
Bit No.
0-15 Heartbeat time
16 - 23 Node address of the
controller.
24 - 31 Reserved, value 0.
1017
h
0 producer_
heartbeat_time
0
0 {1 ms} 65536
VAR UINT1
6
RW
Time between two
heartbeat telegrams.
If the controller starts with
a time unequal zero, the
boot-up telegram is the
first heartbeat.
0 Function is deactivated.
1018
h
0 identity_object
ARR UINT8 RO
Not used.
1 vendor_id
UINT3
2
RO
Manufacturer’s code
2 product_code
UINT3
2
RO
Product code
03A30018
h
3 revision_number
UINT3
2
RO
Firmware version
4 serial_number
UINT3
2
RO
Serial number of hardware