Parameter setting
Loading and saving of parameter sets
Description of the objects
7
73
KHB 13.0003-EN 2.0
7.1.2 Description of the objects
Index Name Possible settings
Characteristics
Lenze Selection Description
1010
h
Store_parameters
0 largest_supported_
subindex
VAR UINT8 RO —
1 save_all_
parameters
00000001
h
00000000
h
{1
h
} 65766173
h
— UINT32 RW —
Accepting the default
parameter set in the
application parameter set.
00000000
h
Default parameter set is not
accepted.
65766173
h
Save Default parameter set is
accepted.
1011
h
Restore_default_
parameters
1 restore_all_default_
parameters
00000001
h
00000000
h
{1
h
} 64616F6C
h
VAR UINT32 RW —
Loading the default
parameter set, only possible
when the power stage is
deactivated.
The CAN communication
parameters (node No., baud
rate and operating mode)
remain unchanged.
64616F6C
h
Load Loading the default
parameter set.
00000001
h
Read access: Reset to default
values.