Manual

Single-axis controllers
Wiring
Devices in the range 145 ... 695 A (75 ... 370 kW)
4
122
EDS94SPP101 EN 7.1
External brake resistor
Terminal X105 Labelling Description
Rb1
Rb2
Connection of external brake resistor
Connection for the PE conductor with M8 ring cable lug.
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Device size 8S:
Flexible
With wire end ferrule
95 000 14 124 Inbus 5
DC bus
Terminal X100 Labelling Description
+UG
-UG
Alternative option for DC-bus voltage connection (compatible to
9300 series).
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Device size 8S:
Flexible
With wire end ferrule
95 000 14 124 Inbus 5
Tip!
Now mount the barrier between mains input and power terminals, if had been
removed to have more free space for wiring.