5.3 Rated data
The E94AMxExxx4 devices can be used in the voltage range of 260 ... 775 V DC.
Note!
To ensure a faultless operation of the devices the code C00173 must be set
according to the mains voltage connected.
Emergency operation
Operation of the E94ASxxxx4 devices with an emergency voltage supply at +UG, -UG, is
possible from U
DC
260 V. The settings in C00173 and C00174 are to be adapted
accordingly.
Operation of the E94AMxxxx4 devices with an emergency voltage supply at +UG, -UG, is
possible with U
DC
260 V. The settings in C00173 and C00174 are to be adapted
accordingly. A 24-V supply at X2 is required.
5.3.1 Overview
Input data
Voltage Frequency Current [A]
Number of
phases
[V] [Hz] max. +45 °C c max. +55 °C c
E94AMxE0024 325/565/705 0(DC) 2.6/2.6/2.3 2.0/2.0/1.7 2
E94AMxE0034 325/565/705 0(DC) 4.3/4.3/3.8 3.2/3.2/2.9 2
E94AMxE0044 325/565/705 0(DC) 6.7/6.7/5.9 5.0/5.0/4.4 2
E94AMxE0074 325/565/705 0(DC) 12.1/12.1/10.6 9.1/9.1/8.0 2
E94AMxE0094 325/565/705 0(DC) 15.4/15.4/13.5 11.6/11.6/10.1 2
E94AMxE0134 325/565/705 0(DC) 20.6/20.6/18.0 15.5/15.5/13.5 2
E94AMxE0174 325/565/705 0(DC) 25.7/25.7/22.5 19.3/19.3/16.9 2
E94AMxE0244 325/565/705 0(DC) 35.5/35.5/31.1 26.3/26.3/23.3 2
E94AMxE0324 325/565/705 0(DC) 48.0/48.0/38.9 36.0/36.0/29.1 2
c Temperature in the control cabinet