Manual

Multi-axis controllers
Rated data
Overview
5
164
EDS94SPP101 EN 7.1
Output data
Voltage Frequency
1)
Current [A]
Number of
phases
Type [V] [Hz] max. +45 °C
c
max. +55 °C
c
E94AMxE0024 0 - 230/400/500 0 - 599 1.5/1.5/1.3 1.1/1.1/1.0 3
E94AMxE0034 0 - 230/400/500 0 - 599 2.5/2.5/2.2 1.9/1.9/1.7 3
E94AMxE0044 0 - 230/400/500 0 - 599 4/4/3.5 3/3/2.6 3
E94AMxE0074 0 - 230/400/500 0 - 599 7/7/6.1 5.3/5.3/4.6 3
E94AMxE0094 0 - 230/400/500 0 - 599 9.3/9.3/8.2 7.0/7.0/6.2 3
E94AMxE0134 0 - 230/400/500 0 - 599 13/13/11.4 9.8/9.8/8.6 3
E94AMxE0174 0 - 230/400/500 0 - 599 16.5/16.5/14.4 12.4/12.4/10.8 3
E94AMxE0244 0 - 230/400/500 0 - 599 23.5/23.5/20.6 17.6/17.6/15.5 3
E94AMxE0324 0 - 230/400/500 0 - 599 32.0/32.0/25.9 24.0/24.0/19.4 3
c Temperature in the control cabinet
1)
The limitation to 599 Hz does not apply to the ”servo control” modes (see C00006=1or2).Generallyapplies:the
output frequency is limited to 1/8 of the selected chopper frequency (see C00018).
Power loss P
V
[W]
Type U
Lr
= 230 V U
Lr
= 400 V U
Lr
= 500 V when controller is inhibited
E94AMxE0024 65 80 95
40
E94AMxE0034 75 95 110
E94AMxE0044 90 120 130
E94AMxE0074 105 145 170
E94AMxE0094 130 170 205
E94AMxE0134 160 215 255
E94AMxE0174 185 255 300
E94AMxE0244 235 320 385
E94AMxE0324 290 405 490