Manual
Multi-axis controllers
Rated data
Devices for 400/500V-mains
5
165
EDS94SPP101 EN 7.1
5.3.2 Devices for 400/500V-mains
5.3.2.1 Operation on 230 V
AC
mains
Basis of the data
Mains Voltage
U
DC
[V]
Voltage range
U
DC
[V]
Frequency range
f[Hz]
2/PE DC 325 260-0%...370+0% -
Input current at I
aN8
Output power Motor power
(typical)
(without external mains
choke)
8kHz,U,V,W 8kHz,4pol.ASM
Type I
DC
[A] S
aN8
[kVA] P
aN
[kW] P
aN
[hp]
E94AMxE0024 2.6 0.6 0.18 0.25
E94AMxE0034 4.3 1.0 0.37 0.5
E94AMxE0044 6.7 1.6 0.75 1
E94AMxE0074 12.1 2.8 1.5 2
E94AMxE0094 15.4 3.7 2.2 3
E94AMxE0134 20.6 5.2 3 4
E94AMxE0174 25.7 6.6 4 5.5
E94AMxE0244 35.5 9.4 5 7.5
Output currents [A] at switching frequency
2kHz 4kHz 8kHz 16 kHz
4)
Type I
aN2
I
aM2
I
aN4
I
aM4
I
aN8
I
aM8
I
aN16
E94AMxE0024 1.9 6.0 1.9 6.0 1.5 4.8 1.1
E94AMxE0034 3.1 10.0 3.1 10.0 2.5 8.0 1.9
E94AMxE0044 5.0 16.0 5.0 16.0 4.0 12.8 3.0
E94AMxE0074 8.8 21.0 8.8 21.0 7.0 16.8 5.3
E94AMxE0094 11.7 28.0 11.7 28.0 9.3 22.4 7.0
E94AMxE0134 16.3 39.0 16.3 39.0 13.0 31.2 9.8
E94AMxE0174 20.6 49.5 20.6 49.5 16.5 39.6 12.4
E94AMxE0244 29.4 70.5 29.4 70.5 23.5 47.0 17.6
I
aN2
Rated value of permanent output current at a frequency of ≥ 0Hz
I
aM2
Maximum output current (overload current) at frequency ≥ 0Hz
z Periodic load change of 0.5 s with I
aM2
and recovery time of 4.5 s with
75 % I
aN2
I
aN4
,I
aN8,
I
aN16
Rated value of continuous output current at a frequency of ≥ 5Hz
(reduce to 0.66 * I
aNx
for 0 ... 5 Hz)
I
aM4
,I
aM8
Maximum output current (overload current) at frequency ≥ 5Hz
(reduce to 0.66 * I
aMx
for 0 ... 5 Hz)
z Periodic load change of 0.5 s with I
aMx
and recovery time of 4.5 s with
75 % I
aNx
z Can be achieved using the setting ”x kHz fixed” in C00018
bold Nominal value I
aN