Manual
Multi-axis controllers
Wiring
Devices in the range 2 ... 32 A (0.37 ... 15 kW)
5
192
EDS94SPP101 EN 7.1
Motor
Terminal X105
(right part)
Labelling Description
U
V
W
Connection of the motor phases
Functional earth
Connect the shields of the motor phases and of the optional motor
brake control separately and with a surface as large as possible to
the shield sheet. Use EMC wire clamp or EMC shield clamp for
fixing.
Connection for the PE conductor on the motor side with M5 ring
cable lug
SSP940X105
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Devicesizes1+2:
flexible
with wire end ferrule
2.5
12 0.5 ... 0.6 4.5 ... 6.2 PZ0
Device size 3:
flexible
with/without wire end
ferrule
10/16 6 1.2 ... 1.5 10.6 ... 13.3 PH1
10
23
a
b
c
d
e
M5
U
V
W
BD1/T1
BD2/T2
PE
SSP94MOTL1
Fig. 5-11 Stripping lengths of the motor cable
Dimensions [mm]
Type a b c d e
Device size 1 80 8 25 150 8
Device size 2 90 8 30 160 8
Device size 3 100 10 30 170 8