Manual

Multi-axis controllers
Control terminals
5
207
EDS94SPP101 EN 7.1
Digital inputs
The controller is provided with freely c onfigurable digital inputs which can be used for
touch probe measurement (edge-controlled event).
The control input RFR for controller enable is firmly connected with the device control. It
must be wired to enable the controller with a HIGH signal.
Electrical data
24O
(external voltage source,
optional)
Rated voltage
24 V
According to IEC 61131-2
Current consumption Max. 50 mA
RFR
DI1
...
DI8
Switching level According to IEC 61131-2
LOW 0 V ... +5 V
HIGH +15 V ... +30 V
Input current Max. 8 mA
Note!
Digital inputs and digital outputs have separated reference potentials (GI and
GO). If you interconnect inputs and outputs, the reference potentials are
connected as well by an external bridge.
GND
Out
01
DI8
DI...
DI2
DI1
RFR
GI
X5
DI8
DI...
DI2
DI1
RFR
GI
X5
DO4
DO3
DO2
DO1
24O
GO
X4
SSP94X5DI1
Fig. 5-17 Wiring principle
Wiring of an external digital signal, e.g. a PLC
Wiring with a slave drive
X4 Terminal for the digital outputs
X5 Terminal for the digital inputs
Out digital output signal, e.g. of a control
GND Earth reference potential