Manual
Multi-axis controllers
Control terminals
5
208
EDS94SPP101 EN 7.1
Terminal X5 Labelling Description
GI GND digital in
RFR Controller enable
DI1 Digital input 1
DI2 Digital input 2
DI3 Digital input 3
DI4 Digital input 4
DI5 Digital input 5
DI6 Digital input 6
DI7 Digital input 7
9400SSP000X5
DI8 Digital input 8
Terminal data
Conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Diagnostics/keypad
The following can be connected to this interface:
ƒ USB diagnostic adapter E94AZCUS
or
ƒ Keypad E94AZKAE.
The diagnostic adapter and a computer with the Lenze software »Engineer« serve to carry
out comprehensive settings, e.g. for initial commissioning.
The keypad enables experienced users to check or change individual settings.
Terminal X6 Labelling Description
Internal interface, RJ69 socket, for keypad or diagnostic adapter
9400SSP000X6