Manual

Regenerative power supply modules
Rated data (devices for 400/500V mains)
Operation at a rated mains voltage of 500 V
7
270
EDS94SPP101-7.1
7.3.3 Operation at a rated mains voltage of 500 V
Basis of the data
Mains Voltage Voltage range Frequency range
U
LN
[V] U
LN
[V] f[Hz]
3/PE AC 500 400-0%...550+0% 45 ... 65
Input data (on the supply side)
Voltage Frequency Current [A]
Number of
phases
[V] [Hz] max. +45 °C c max. +55 °C c
E94ARNE0134
In motor mode
500 50/60 26 19.5 3
In generator mode
500 50/60 13 9.8 3
E94ARNE0244
In motor mode
500 50/60 47 35 3
In generator mode
500 50/60 23.5 17.6 3
c Temperature in the control cabinet
Voltage Continuous input power
Type [V] S
L
[kVA]
E94ARNE0134
In motor mode
500 22.5
In generator mode
500 11.2
E94ARNE0244
In motor mode
500 40.7
In generator mode
500 20.3