Manual
Regenerative power supply modules
Final works
Initial commissioning on 400 V mains voltage
7
308
EDS94SPP101-7.1
7.7 Final works
7.7.1 Initial commissioning on 400 V mains voltage
After the installation has been carried out according to the Mounting Instructions, the
regenerative power supply module can be operated on a mains voltage of 400 V.
The regenerative feedback is activated via the digital input RFR.
How to proceed:
1. Switch on 24 V supply voltages.
– for the mains filter
– for the regenerative power s upply module (optional)
2. Switch on 400 V mains voltage.
3. Activate/deactivate regenerative feedback via the digital input RFR.
7.7.2 Initial commissioning on 230 V or 500 V mains voltage
For operation on a mains voltage of 230 V or 500 V, first the mains voltage within the
regenerative power supply module has to be set. The setting is effected in C00173 and can
be carried out using a keypad o r the Lenze PC software »Engineer«.
For commissioning you require:
ƒ An EZAEBKx00xkeypad,
or
ƒ A computer with Windows® operating system (XP or 2000)
ƒ The Lenze PC software »Engineer«
ƒ A connection to the regenerative power supply module via an interface, e. g.
– Diagnostic interface X6 with USB diagnostic adapter
– CAN system bus
– Communication modules in the expansion slots M1/M2
ƒ The software manual for the technology application used
ƒ The communication manual (KHB) for the network of the automation platform
ƒ Switch on 24 V supply voltages:
– for the mains filter
– for the regenerative power s upply module
After the setting has been carried out according to the mains voltage available:
1. Switch on mains voltage.
2. Activate/deactivate regenerative feedback via the digital input RFR.
7.7.3 Further settings
Follow the instructions of the software and/or read the documentation for the
parameterisation of the regenerative power supply module.