Manual

Single-axis controllers
General data and operating conditions
4
41
EDS94SPP101 EN 7.1
General electrical data
Motor cable requirements
Capacitance per unit length
2.5 mm
2
/AWG 14 C
Core/core
/C
Core/shield
< 75/150 pF/m
4mm
2
/AWG 12 C
Core/core
/C
Core/shield
< 150/300 pF/m
Electric strength
VDE 0250-1 U
0
/U
=
0.6/1.0 kV
(U
0
= r.m.s. value of external conductor to PE,
U = r.m.s. value of external conductor to external conductor)
UL U 600 V
(U = r.m.s. value of external conductor to external conductor)
Maximum motor and feedback cable lengths
(for shielded motor cable with rated mains voltage)
Type Device size [m]
E94AMxE0024
E94AMxE0034
E94AMxE0044
1
50
E94ASxE0024
E94ASxE0034
E94AMxE0074
E94AMxE0094
2 100
E94ASxE0044
E94ASxE0074
E94AMxE0134
E94AMxE0174
E94AMxE0244
3 100
E94AMxE0324 3 100
E94ASxE0134
E94ASxE0174
E94ASxE0244
3 100
E94ASxE0324
E94ASxE0474
E94ASxE0594
6 100
E94ASxE0864
E94ASxE1044
7 100
E94ASxE1454 8S 150
E94ASxE1724
E94ASxE2024
8 150
E94ASxE2454
E94ASxE2924
E94ASxE3664
9 150
E94ASxE4604
E94ASxE5724
E94ASxE6354
E94ASxE6954
10 150
If EMC conditions must be met, the permissible cable lengths can be reduced.
Tab. 4-1