Manual

Single-axis controllers
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 400 V
4
55
EDS94SPP101 EN 7.1
Output currents [A] at switching frequency
2kHz 4kHz 8kHz 16 kHz
4)
Type I
aN2
I
aM2
I
aN4
I
aM4
I
aN8
I
aM8
I
aN16
E94ASxE0024 1.9
3)
6.0 1.9
3)
6.0 1.5 4.8 1.1
E94ASxE0034 3.1
3)
10.0 3.1
3)
10.0 2.5 8.0 1.9
E94ASxE0044 5.0
3)
16.0 5.0
3)
16.0 4.0 12.8 3.0
E94ASxE0074 8.8
3)
21.0 8.8
3)
21.0 7.0 16.8 5.3
E94ASxE0134 16.3
3)
39.0 16.3
3)
39.0 13.0 31.2 9.8
E94ASxE0174 20.6
3)
49.5 20.6
3)
49.5 16.5 39.6 12.4
E94ASxE0244 29.4
3)
58.8 29.4
3)
58.8 23.5 47.0 17.6
E94ASxE0324 38.4 76.8 38.4 76.8 32.0 56.0 16.8
E94ASxE0474 47.0 94.0 47.0 94.0 41.0 82.0 21.5
E94ASxE0594 59.0 118 59.0 118 41.0 82.0 21.5
E94ASxE0864 86.0 172 86.0 172 73.0 146 38.3
E94ASxE1044 104 208 104 208 78.0 156 40.9
E94ASxE1454 145 261 145 261 102 184 -
E94ASxE1724 172 310 172 310 120 216 -
E94ASxE2024 202 364 202 364 131 236 -
E94ASxE2454 245 441 209 376 160 288 -
E94ASxE2924 292 526 250 450 191 344 -
E94ASxE3664 366 659 313 563 240 432 -
E94ASxE4604 460 828 368 662 260 468 -
E94ASxE5724 572 1030 458 824 286 515 -
E94ASxE6354 635 1143 508 914 318 572 -
E94ASxE6954 695 1251 556 1001 348 626 -
I
aN2
Rated value of permanent output current at a frequency of 0Hz
I
aM2
Maximum output current (overload current) at frequency 0Hz
E94ASxE0024 ... E94ASxE1044:
z Periodic load change of 0.5 s with I
aM2
and recovery time of 4.5 s with
75 % I
aN2
E94ASxE1454 ... E94ASxE6954:
z Periodic load change of 10 s with I
aM2
and recovery time of 50 s with
75 % I
aN2
I
aN4
,I
aN8,
I
aN16
Rated value of continuous output current at a frequency of 5Hz
(reduce to 0.66 * I
aNx
for 0 ... 5 Hz)
I
aM4
,I
aM8
Maximum output current (overload current) at frequency 5Hz
(reduce to 0.66 * I
aMx
for 0 ... 5 Hz)
z Can be achieved using the setting ”x kHz fixed” in C00018
E94ASxE0024 ... E94ASxE1044:
z Periodic load change of 0.5 s with I
aMx
and recovery time of 4.5 s with
75 % I
aNx
E94ASxE1454 ... E94ASxE6954:
z Periodic load change of 10 s with I
aM2
and recovery time of 50 s with
75 % I
aN2
bold Nominal value I
aN
3)
Operation with permanent currents > I
aN8
requires an external mains choke.