Single-axis controllers
Rated data (devices for 400/500V mains)
Overcurrent operation
4
73
EDS94SPP101 EN 7.1
500 V
Type
I [A] in a cycle of 5 seconds c
f=2kHz f=4kHz f=8kHz f = 16 kHz
E94ASxE0024 6.0 1.4 6.0 1.4 4.2 1.0 - -
E94ASxE0034 10.0 2.3 10.0 2.3 7.0 1.6 - -
E94ASxE0044 16.0 3.8 16.0 3.8 11.2 2.6 - -
E94ASxE0074 21.0 6.6 21.0 6.6 14.7 4.6 - -
E94ASxE0134 39.0 12.2 39.0 12.2 27.3 8.5 - -
E94ASxE0174 49.5 15.5 49.5 15.5 34.7 10.8 - -
E94ASxE0244 58.8 22.0 58.8 22.0 41.1 15.4 - -
E94ASxE0324 76.8 28.8 76.8 28.8 56.0 21.0 - -
E94ASxE0474 94.0 35.3 94.0 35.3 71.6 26.7 - -
E94ASxE0594 118 44.3 118 44.3 71.8 26.8 - -
E94ASxE0864 172 64.5 172 64.5 128 48.2 - -
E94ASxE1044 208 78.0 208 78.0 137 51.0 - -
E94ASxE1454 261 109 261 109 196 81.2 - -
E94ASxE1724 310 129 310 129 232 96.3 - -
E94ASxE2024 364 152 364 152 273 113 - -
E94ASxE2454 441 184 377 157 289 120 - -
E94ASxE2924 526 219 450 187 345 143 - -
E94ASxE3664 659 275 564 234 432 179 - -
E94ASxE4604 828 345 662 276 469 193 - -
E94ASxE5724 1030 429 824 343 515 217 - -
E94ASxE6354 1143 476 914 381 572 241 - -
E94ASxE6954 1251 521 1001 417 626 264 - -