Commissioning
Important codes for quick commissioning
7
176
EDK82EV903 DE/EN/FR 5.1
7.4 Important codes for quick commissioning
The following table describes the codes mentioned in the commissioning examples. A
description of all codes can be found in the system manual, chapter "Function library".
How to read the code table
Column Abbreviation Meaning
Code Cxxxx Code Cxxxx l The parameter value of the code can be defined
differently within each parameter set
l The parameter value is accepted immediately
(ONLINE)
1 Subcode 1 of Cxxxx
2 Subcode 2 of Cxxxx
* Parameter value of the code is the same for all parameter sets and can be
changed in parameter set 1
Keypad E82ZBC Changed parameter of the code or subcode will be
accepted after pressing
Keypad XT EMZ9371BC Changed parameter of the code or subcode will be
accepted after pressing
Keypad E82ZBC Changed parameter of the code or subcode will be
accepted after pressing if the controller is inhibited
Keypad XT EMZ9371BC Changed parameter of the code or subcode will be
accepted after pressing if the controller is
inhibited
(A) Code, subcode or selection only available for operation with application I/O
uSEr Code is contained in the Lenze setting in the USER menu
Designation Name of the code
Lenze Lenze setting (value at delivery or after restoring the delivery status with C0002)
à Further information can be obtained from the "IMPORTANT" column
Selection 1 {%} 99 Min. value {unit} max. value
IMPORTANT − Brief, important explanations
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0002*
uSEr
Parameter set
management
0 0 Ready PAR1 ... PAR4:
l Parameter sets of the controller
l PAR1 ... PAR4 also contain the
parameters for the function
modules standard I/O, application
I/O, AS interface, system bus (CAN)
FPAR1:
l Module−specific parameter set of
the fieldbus function modules
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
l FPAR1 is saved in the function
module
Restoring the
delivery status
1 Lenze setting ð PAR1
Restore the delivery status in the
parameter set selected
2 Lenze setting ð PAR2
3 Lenze setting ð PAR3
4 Lenze setting ð PAR4
31 Lenze setting ð FPAR1 Restore the delivery status in the
fieldbus function module
61 Lenze setting ð PAR1 + FPAR1
Restore the delivery status in the
selected parameter set of the
controller and in the fieldbus function
module
62 Lenze setting ð PAR2 + FPAR1
63 Lenze setting ð PAR3 + FPAR1
64 Lenze setting ð PAR4 + FPAR1