C1511: Configuration of process output data
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1511 23064
d
=
5A18
h
FIX32
1 (POW1) 17
see table below
2 (POW2) 3
3 (POW3) 4
4 (POW4) 5
5 (POW5) 6
6 (POW6) 7
7 (POW7) 8
8 (POW8) 9
9 (POW9) 10
10 (POW10) 11
The assignment of the up to 10 process data output words (POW) of the master to the bit
control commands or controller setpoints can be freely configured.
Selection Scaling
1 FIF control word 1 (FIF−CTRL1) 16 bits
2 FIF control word 2 (FIF−CTRL2) 16 bits
3 Setpoint 1 (NSET1−N1) ±24000 º ±480 Hz
4 Setpoint 2 (NSET1−N2) ±24000 º ±480 Hz
5 Additional setpoint (PCTRL1−NADD) ±24000 º ±480 Hz
6 Actual process controller value (PCTRL1−ACT) ±24000 º ±480 Hz
7 Process controller setpoint (PCTRL1−SET1) ±24000 º ±480 Hz
8 Reserved
9 Torque setpoint/torque limit value (MCTRL1−MSET) 2
14
º100 % rated motor torque
10 PWM voltage (MCTRL1−VOLT−ADD)
(
For special applications only.
^ System manual for 8200 vector
11 PWM angle (MCTRL1−PHI−ADD)
12 Reserved
13 FIF−IN.W1 16 bits or 0 ... 65535
14 FIF−IN.W2 16 bits or 0 ... 65535
15 FIF−IN.W3 0 ... 65535
16 FIF−IN.W4 0 ... 65535
17 DRIVECOM control word (DRIVECOM−CTRL) 16 bits
18 Reserved
19 PROFIdrive control word (PROFIdrive−CTRL) 16 bits