C1516: Display baud rate
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1516 23059
d
=
5A13
h
g
0 [1] 9
FIX32
0: 12 Mbps
1: 6 Mbps
2: 3 Mbps
3: 1.5 Mbps
4: 500 kbps
5: 187.5 kbps
6: 93.75 kbps
7: 45.45 kbps
8: 19.2 kbps
9: 9.6 kbps
C1517: Display bus device address
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1517 23058
d
=
5A12
h
g 3 [1] 126 FIX32
Display of the valid bus device address, which has been set via the DIP switches S1 ... S7 or
via code C1509.
C1520: Display of all words to master
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1520 23055
d
=
5A0F
h
g 0 [1] 65535 U16
1 (PIW1)
...
10 (PIW10)
Display of the master’s process data input words PIW1 ... PIW10 in the different subcodes.
All words are displayed. Only the configured words are valid.
The assignment of the bit status information or the actual controller values to the up to 10
process data input words (PIW) of the master can be freely configured via code C1510.