User guide

4 Technical data
General data
EDK82ZAFUC010 DE/EN/FR 4.0
50
H1_Daten−IP20
4 Technical data
General data
Field Values
Order designation E82ZAFUC010
Communication profile CANopen, DS301 V4.02
Communication medium DIN ISO 11898
Network topology
Line terminated at both ends with 120 W resistor
Max. number of nodes Max. 127 (with repeater)
Max. possible number of
nodes per segment
l For E82ZAFUC010: 106 (max.)
l In the case of different nodes:
see notes for mixed operation 59
CANopen nodes Slave
Baud rate [kbps] 10, 20, 50, 125, 250, 500, 1000
Process data words 1 ... 12 words
Operating conditions
Ambient conditions
Climate
Storage
IEC/EN 60721−3−1 1K3 (−25 to +60 °C)
Transport IEC/EN 60721−3−2 2K3 (−25 to +70 °C)
Operation Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
Pollution EN 61800−5−1 Degree of pollution 2
Degree of protection IP20 (protection against accidental contact according to NEMA 250 type 1)