7 Diagnostics & troubleshooting
7.4 Monitoring
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4 Monitoring
The controller is provided with various monitoring functions which protect the drive against
impermissible operating conditions.
If a monitoring function responds,
an entry will be made into the logbook
of the controller,
the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will be
triggered,
the status of the internal device control changes according to the selected response, controller
inhibit is set, and the "DRV- ERR" LED on the front of the controller goes on:
Response
Entry in the
logbook
Display in
C00168
Pulse inhibit Controller
inhibit
Acknowledgem
ent required
LED "DRV-ERR"
None OFF
Fault 
Trouble 
TroubleQSP 
WarningLocked 
Warning 
Information OFF
System error 
Mains switching
is required!