User Manual

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05 59
8 Adapting the application individually
8.2 Activating additional functions in the signal flow
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.2.1 Speed limit values
C00635
C00636
C02611/x
L_NSet_1: nMaxLimit
Maximum speed setpoint for speed setpoint limitation
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 199.99 %
L_NSet_1: nMinLimit
Minimum speed setpoint for speed setpoint limitation
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 -199.99 %
MCK: Limitations
Speed setpoint limits for the determination of limited validity ranges
Note:
Traversing with setpoints through resulting blocking zones is executed with the ramp set in C02610/2
:
setpoint range synchronisation range
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C02611/1 199.99 % MCK: Pos. max. speed
• Upper limit of the speed setpoint limitation in
positive direction of rotation.
C02611/2 0.00 % MCK: Pos. min. speed
• Lower limit of the speed setpoint limitation in
positive direction of rotation.
C02611/3 0.00 % MCK: Neg. min. speed
• Lower limit of the speed setpoint limitation in
negative direction of rotation.
C02611/4 199.99 % MCK: Neg. max. speed
• Upper limit of the speed setpoint limitation in
negative direction of rotation.
Sync
Sync
v
t
C02611/1
C02611/2
C02611/3
C02611/4
C02610/2
0
1
0
nSpeedSetValue_a nSpeedSetValue_a_
C02610/2