Manual

EDS84AYCEC EN 3.0 - 09/2012 L 67
E84AYCEC communication manual (Ethernet POWERLINK)
Parameter reference
Parameters of the communication module
C13003
C13004
Parameter | Name:
C13003 | 0x1E40.5 IP Address Router
Data type: UNSIGNED_32
Index: 11572
d
= 2D34
h
The code declares the IP address of the router which connects the EPL segment to the higher-level network. The
standard entry corresponds to the standard router address of the EPL specification:
192.168.100.254
Permissible entries replace the lowest-order byte of the standard entry with the EPL address of the node which has
the function of a router.
Setting range (min. value | unit | max. value)
0.0.0.0
(0x00000000)
255.255.255.255
(0xFFFFFFFF)
Subcodes Lenze setting Info
C13003/1 3232261374 IP address router
Lenze setting: 0xC0A864FE = 192.168.100.254
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13004 | 0x1030.5 MAC Address
Data type: OCTET_STRING
Index: 11571
d
= 2D33
h
The code indicates the physical address (MAC address) of the Ethernet interface of the communication module.
When the communication module is produced, the MAC address is assigned unequivocally worldwide and provides
addressing on the lowest level.
Subcodes Info
C13004/1 MAC Address (octet string[6])
00-0A-86-xx-yy-zz
00-0A-86 = Lenze
xx-yy-zz = consecutive number
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT