Implemented CIP™ objects
"AC Drive Profile" objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Run/stop event
Relationships between Run1 and Run2:
Run1 and Run2 trigger:
Supported service codes
13 Get FaultCode UINT DRIVECOM error code of the error causing
the Faulted status.
Mapping of Lenze device errors to
DRIVECOM errors ( 87)
15 Get CtrlFromNet BOOL Status of run/stop control
• 0: Run/stop control via local setting on
the device or terminal
• 1: Run/stop control via network (e.g. from
the scanner)
Run1 / Run2 Starter Drive
Contactor Starter Reverser Speed Soft start
Run1 Close Run RunFwd RunLow RunRamp1 RunFwd
Run2 No Action No Action RunRev RunHigh RunRamp2 RunRev
Run1 Run2 Trigger event Run type
00StopNo Action
0 1 0 Run Run1
00 1 Run Run2
0 1 0 1 No Action No Action
1 1 No Action No Action
1 0 1 Run Run2
11 0 Run Run1
Service code
[hex]
Name Description
0x01 Get_Attributes_All Outputs a list of the attributes and the attribute's values for
a certain object.
0x0E Get_Attribute_Single Outputs the value of a certain attribute.
0x10 Set_Attribute_Single Changes the value of a certain attribute.
Attribute
ID
Service Name Data type Value