Commissioning
Establishing an online connection via EtherNet/IP with the Lenze »Engineer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In the »Engineer«, you can use the Online Set communication path and go online menu command
to select the EtherNet/IP communication path. The previously configured EtherNet/IP nodes are
shown in the "Communication path" dialog window:
If the device access path is not configured correctly, the IP address of the drive selected in the
display field can be entered manually here.
Via the Search/Enter button, you can establish a connection to devices which have not
appeared in the display field. Corresponding settings for this can be made in the "Enter IP Address"
dialog window that will appear:
Here you can enter an IP address manually or execute the following actions using the buttons:
Execute the console command Ping.
Assign the IP address via the Configurator.
Setting via the EtherNet/IP configurator of the »Engineer«
( 31)
Select the device access path to the desired drive by clicking Find.
After having established the online connection, you can continue work with the »Engineer« as
usual.