C13017
C13018
C13019
Parameter | Name:
C13017 | Ethernet Config Control
Data type: UNSIGNED_16
Index: 11558 = 0x2D26
Setting of the baud rate for the Ethernet connections
Selection list
0Auto-Negotiation
1 10 Mbps
2 100 Mbps
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved
10 Reserved
11 Reserved
12 Reserved
Subcodes Lenze setting Info
C13017/1 0: Auto-Negotiation Ethernet setting port X31
C13017/2 0: Auto-Negotiation Ethernet setting port X32
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13018 | Multicast Config Alloc Control
Data type: UNSIGNED_8
Index: 11557 = 0x2D25
Selection for multicast IP addressing via instance attribute 9 (Mcast Config) in the TCP/IP Interface Object (245 /
0xF5) ( 126)
Selection list (Lenze setting printed in bold)
0 Default Allocation Algorithm
1 Multicast IP Start Address
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13019 | Multicast Config TTL Value
Data type: UNSIGNED_8
Index: 11556 = 0x2D24
Setting of the multicast TTL value for the validity time of data packets in the EtherNet/IP network
(Instance attribute 8 (TTL Value) in the TCP/IP Interface Object (245 / 0xF5)
( 126))
Setting range (min. value | unit | max. value) Lenze setting
1 255 1