5 Function blocks
5.2 L_CamContactor - cam group with switch-on and switch-off dynamisation
146
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.5 Dynamic displacement of the cams
In C05521 and C05522 a time displacement of the switch-on and switch-off positions can be set for
the cams, e. g. to implement a compensation of delay times of switching elements connected.
A positive time period causes the cam to be switched earlier, a negative time period accordingly
causes the switching operation to occur later.
For position-time cams only a time displacement of the switch-on position is effected via
C05521; the setting in C05522 has no effect.
Dynamic cam sampling is limited by the half-cycle period. If the limitation is activated, the
bError output is set to TRUE and the limitation is signalled via error bit 15 in C05529.
[5-8] Displacement of the switch-on and switch-off position for different speeds
5.2.6 Selection of the cam data
The contactor data can either be part of the cam data available in the memory module or be deter-
mined by a master control via PDOs or SDOs.
If the FB uses the contactor data stored in the memory module, the corresponding track number
must be determined in the dnTrackNumber input.
•The FBL_CamSetContDataPDO
serves to determine the contactor data via inputs/PDOs. The
contactor data are transferred to the FB L_CamContactor via the ContactorData input (see fig.
[5-9]
).
•The FBL_CamSetContDataSDO
serves to determine the contactor data via inputs/SDOs. The
contactor data are transferred to the FB L_CamContactor via the ContactorData input (see fig.
[5-10]
).
Positive time displacement of the switch-on position (causes earlier switch-on)
Negative time displacement of the switch-off position (causes late switch-off)
bOut
dnPosIn_p
t
t
 
Speed A Speed 2 * A

Note!
If the inputs dnTrackNumber and ContactorData are assigned simultaneously, the con-
tactor data transferred via the ContactorData input is used. If this connection is separa-
ted, it is changed over to the contactor data stored in the memory module.