User guide
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 159
5 Function blocks
5.5 L_CamPosMarker - reading out position marks from cam data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
dnXPosMarker2_p
DINT
Position marker 2: x position in [increments]
• C05536/3 indicates the position in the real unit of the machine.
dnYPosMarker2_p
DINT
Position marker 2: y position in [increments]
• C05537/3 indicates the position in the real unit of the machine.
dnXPosMarker3_p
DINT
Position marker 3: x position in [increments]
• C05536/4 indicates the position in the real unit of the machine.
dnYPosMarker3_p
DINT
Position marker 3: y position in [increments]
• C05537/4 indicates the position in the real unit of the machine.
dnXPosMarker4_p
DINT
From library V01.02.xx.xx
Position marker 4: x position in [increments]
• C05536/5 indicates the position in the real unit of the machine.
dnYPosMarker4_p
DINT
From library V01.02.xx.xx
Position marker 4: y position in [increments]
• C05537/5 indicates the position in the real unit of the machine.
dnXPosMarker5_p
DINT
From library V01.02.xx.xx
Position marker 5: x position in [increments]
• C05536/6 indicates the position in the real unit of the machine.
dnYPosMarker5_p
DINT
From library V01.02.xx.xx
Position marker 5: y position in [increments]
• C05537/6 indicates the position in the real unit of the machine.
dnXPosMarker6_p
DINT
From library V01.02.xx.xx
Position marker 6: x position in [increments]
• C05536/7 indicates the position in the real unit of the machine.
dnYPosMarker6_p
DINT
From library V01.02.xx.xx
Position marker 6: y position in [increments]
• C05537/7 indicates the position in the real unit of the machine.
dnXPosMarker7_p
DINT
From library V01.02.xx.xx
Position marker 7: x position in [increments]
• C05536/8 indicates the position in the real unit of the machine.
dnYPosMarker7_p
DINT
From library V01.02.xx.xx
Position marker 7: y position in [increments]
• C05537/8 indicates the position in the real unit of the machine.
XAxisData Machine parameters of the x axis
• Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
YAxisData Machine parameters of the y axis
• Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
bError
BOOL
"Error" status
TRUE An error has occurred (group signal).
• For details see display parameter C05539.
Parameter Possible settings Information
C05530/1 String of digits Position unit of x axis
•Read only
C05530/2 String of digits Designation of the x axis
•Read only
C05530/3 String of digits Position unit of y axis
•Read only
C05530/4 String of digits Designation of the y axis
•Read only
Identifier/data type Value/meaning