User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 159
5 Function blocks
5.5 L_CamPosMarker - reading out position marks from cam data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
dnXPosMarker2_p
DINT
Position marker 2: x position in [increments]
C05536/3 indicates the position in the real unit of the machine.
dnYPosMarker2_p
DINT
Position marker 2: y position in [increments]
C05537/3 indicates the position in the real unit of the machine.
dnXPosMarker3_p
DINT
Position marker 3: x position in [increments]
C05536/4 indicates the position in the real unit of the machine.
dnYPosMarker3_p
DINT
Position marker 3: y position in [increments]
C05537/4 indicates the position in the real unit of the machine.
dnXPosMarker4_p
DINT
From library V01.02.xx.xx
Position marker 4: x position in [increments]
C05536/5 indicates the position in the real unit of the machine.
dnYPosMarker4_p
DINT
From library V01.02.xx.xx
Position marker 4: y position in [increments]
C05537/5 indicates the position in the real unit of the machine.
dnXPosMarker5_p
DINT
From library V01.02.xx.xx
Position marker 5: x position in [increments]
C05536/6 indicates the position in the real unit of the machine.
dnYPosMarker5_p
DINT
From library V01.02.xx.xx
Position marker 5: y position in [increments]
C05537/6 indicates the position in the real unit of the machine.
dnXPosMarker6_p
DINT
From library V01.02.xx.xx
Position marker 6: x position in [increments]
C05536/7 indicates the position in the real unit of the machine.
dnYPosMarker6_p
DINT
From library V01.02.xx.xx
Position marker 6: y position in [increments]
C05537/7 indicates the position in the real unit of the machine.
dnXPosMarker7_p
DINT
From library V01.02.xx.xx
Position marker 7: x position in [increments]
C05536/8 indicates the position in the real unit of the machine.
dnYPosMarker7_p
DINT
From library V01.02.xx.xx
Position marker 7: y position in [increments]
C05537/8 indicates the position in the real unit of the machine.
XAxisData Machine parameters of the x axis
Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
YAxisData Machine parameters of the y axis
Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
bError
BOOL
"Error" status
TRUE An error has occurred (group signal).
For details see display parameter C05539.
Parameter Possible settings Information
C05530/1 String of digits Position unit of x axis
•Read only
C05530/2 String of digits Designation of the x axis
•Read only
C05530/3 String of digits Position unit of y axis
•Read only
C05530/4 String of digits Designation of the y axis
•Read only
Identifier/data type Value/meaning