User guide
5 Function blocks
5.68 L_DevHomingStateDecoder - status signals of the basic function "Homing"
260
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
The boolean outputs have the following meaning when the value is TRUE:
Bit* Identifier Meaning in case of TRUE
1bActive Homing is active.
2 bDone Homing is completed.
3 bAccDec Acceleration/deceleration phase is active.
5 bCcw Counter-clockwise rotation is active.
7 bHomePosOK Home position is known.
15 bErrorActive Error is active.
16 bRefMarkDetect Pre-stop (home switch) has been detected.
17 bTPDetect Touch probe/zero pulse has been detected.
19 bMinOverride** Override ≤ 1 %
21 bLimProfile Profile data is limited by the basic function "Limiter" (SB LS_Limiter).
22 bLimDir Direction is inhibited by the basic function "Limiter" (SB LS_Limiter).
23 bLimAbort Abort by basic function "Limiter" (SB LS_Limiter).
25 bStoppingActive Stopping (standard stop) is active.
30 bErrPG Error during profile generation.
* With regard to the dnState input signal. ** As of library V02.04.xx.xx