User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 271
5 Function blocks
5.72 L_DevParWriteFix - write parameter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.72 L_DevParWriteFix - write parameter
This FB writes a parameter with the value of the data input dnData ... bData which has been selected
via the dwDataTyp input.
All internal parameters (codes) of the controller can be written to.
From controller software version V08 and library V02.05.xx.xx, parameters of another node con-
nected to the system bus (CAN) can also be written to if a suitable SDO server channel has been
parameterised at the remote node for this purpose.
The parameters of the remote node can be addressed by entering either the code or the CA-
Nopen index.
In contrast to the L_DevWriteParDInt
FB, the parameter of this FB to be written is addressed via
FB inputs and not via parameters.
The FB supports both one-time and cyclic writing in an adjustable time interval.
Function library: LenzeDevice9400 FB is available as of library V02.00.xx.xx!
FB may only be used for firmware as of V1.50!
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Note!
The following applies to the 9400 ServoPLC: The FB must not be called with the same in-
stance in several tasks.