5.74 L_DevReadParDInt - reading parameters of the DINT type
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.74 L_DevReadParDInt - reading parameters of the DINT type
This FB reads parameters of data type "DINT" and outputs the read value via the output dnData for
the application.
Only internal parameters (codes) of the controller can be read.
In contrast to the L_DevParReadFix
FB, the parameter of this FB to be read is addressed via pa-
rameters and not via FB inputs.
The FB supports both one-time and cyclic reading in a parameterisable time interval.
To read a parameter with another data type than "DINT", use the FB L_DevParReadFix
. ( 265)
Inputs
Function library: LenzeDevice9400 FB is available from library V02.00.xx.xx onwards!
FB may only be used for firmware from V1.50 onwards!
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Note!
The following applies to the 9400 ServoPLC: The FB may not be called with the same in-
stance in several tasks.
Identifier/data type Information/possible settings
bExecute
BOOL
Activate a read request.
FALSETRUE If cycle time (C05915) = "0 s":
Read parameter value once
which has been addressed via
C05910 ...C05913.
If cycle time (C05915) > "0 s":
Read parameter value cyclically
which has been addressed via
C05910 ...C05913.
TRUEFALSE Deactivate cyclic reading again.