5 Function blocks
5.80 L_EsClutchPos - clutch (time-controlled)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C05332 Clutch mode
0 Declutching until standstill
(dnOpenPos_p).
1Declutching to basic speed
(dnBaseSpeed_s).
Lenze setting
C05333/1 0.001 s 10.000 Relative declutch time
•With regard to the dnOpenPos_p
standstill position or the
dnBaseSpeed_s basic speed.
• Initialisation: 1.000 s
C05333/2 0.001 s 10.000 Relative clutch-in time
• Relating to the position from
which the output position
dnPosOut_p and input position
dnPosIn_p are synchronous again.
• Initialisation: 1.000 s
C05333/3 0.001 s 10.000 Deceleration time for positive ope-
ning operation
• Relating to the reference speed.
• Initialisation: 1.000 s
C05335/1 -214748.3647 Unit 214748.3647 Input position
•Display of the dnPosIn_p input si-
gnal in the real unit of the machi-
ne.
C05335/2 -214748.3647 Unit 214748.3647 Standstill position
• Position after declutch process
•Display of the dnOpenPos_p input
signal in the real unit of the ma-
chine.
C05335/3 -214748.3647 Unit 214748.3647 Position for "Hard declutching"
• Position to which the dnPosOut_p
output position is set immediate-
ly by setting bLoadPosOut to
TRUE.
•Display of the dnLoadPosOut_p in-
put signal in the real unit of the
machine.
C05336 -214748.3647 Unit/t 214748.3647 Basic speed
•Display of the dnBaseSpeed_s in-
put signal in the real unit of the
machine.
C05337 -214748.3647 Unit 214748.3647 Output position
•Display of the dnPosOut_p output
signal in the real unit of the ma-
chine.
C05338 -214748.3647 Unit/t 214748.3647 Output speed
•Display of the dnSpeedOut_s out-
put signal in the real unit of the
machine.
Parameter Possible settings Information