5.91 L_LdMarkSync - mark synchronisation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.91 L_LdMarkSync - mark synchronisation
When mark synchronisation is performed, this FB calculates the position at which a mark signal
(touch probe signal) occurred. Furthermore, the remaining distance to the setpoint position of the
mark is observed and output.
High-precision detection of the actual TP position for which a mark signal occurred.
Application only in conjunction with modulo measuring systems.
Comparison with a TP setpoint position at which the mark ideally occurs.
Calculation of the TP deviation (= deviation between the actual TP position and the TP setpoint
position).
Feedback of the correcting signal and monitoring of the outstanding TP deviation.
Distance measurement between two mark signals.
Inputs
Function library: LenzeLineDrive
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Note!
The generation of the correcting motion is not part of the L_LdMarkSync FB. For this pur-
pose, use e.g. the L_LdPosCtrlLin
FB (time-controlled correction) or the L_CamSyncIn FB
(path-controlled correction).
Identifier/data type Information/possible settings
bEnable
BOOL
Activate FB
FALSE FB is deactivated: Touch probe signals are not evaluated. A value of
"0" is output at the dnActDifference_p, dnTpDifference_p,
dnTpTpDistance_p and dnTpPos_p outputs.
The value at the dnPosOffset_p output remains unchanged.
TRUE FB is activated: After a touch probe signal has occurred, the outputs
display the described quantities. The monitoring of the remaining TP
deviation (the dnActDifference_p output signal) is switched on.
GQ6WDWH
GQ3RV2IIVHWBS
GQ$FW'LIIHUHQFHBS
GQ7S'LIIHUHQFHBS
GQ7S7S'LVWDQFHBS
GQ7S3RVBS
/B/G0DUN6\QF
E(QDEOH
GQ$FW3RVBS
GQ0DNH8S/HHZD\BV
E7S5HFHLYHG
E5HVHW3RV
GQ7S7LPH/DJ
GQ7S6HW3RVBS
$[LV'DWD
73
&75/