5.99 L_LdVirtualMasterP - virtual master for synchronism
376
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C05011 0.0000 Unit 214000.0000 Target position
The target position must be inside
the cycle.
Initialisation: 0.0000 unit
C05012 0.0000 Unit 214000.0000 Starting position
The starting position must be
inside the cycle.
Initialisation: 0.0000 unit
C05013/1 -214000.0000 Unit/t 214000.0000 Master speed 1
Initialisation: 1.0000 unit/t
C05013/2 -214000.0000 Unit/t 214000.0000 Master speed 2
Initialisation: 1.0000 unit/t
C05014/1 0.0000 Unit/t 214000.0000 Positive inching: Speed
Initialisation: 1.0000 unit/t
C05014/2 0.0000 Unit/t 214000.0000 Negative inching: Speed
Initialisation: 1.0000 unit/t
C05015/1 0.010 s 130.000 Ramp: Inching
Initialisation: 1.000 s
C05015/2 0.010 s 130.000 Ramp: Continuous operation/single
cycle
Initialisation: 1.000 s
C05015/3 0.010 s 130.000 Ramp: Stop
Initialisation: 1.000 s
C05016/1
From library V02.02.xx.xx onwards
Character string Position unit
•Read only
C05016/2
From library V02.02.xx.xx onwards
Character string Speed unit
•Read only
C05017
From library V02.02.xx.xx onwards
-214748.3647 Unit/t 214748.3647 Reference speed
•Read only
For input orientation for speed
entries.
C05024 -2147483647 2147483647 Status
Display of the bit-coded output
signal dnState.
C05025 Master position in the target
•Like output bInTarget
•Read only
0No
1Yes
C05026 -214748.3647 Unit 214748.3647 Cycle
•Read only
C05027 -214748.3647 Unit 214748.3647 Master position at the output
•Display of the dnPosOut_p output
signal in the real unit of the
machine.
C05028 -214748.3647 Unit 214748.3647 External master position at the input
•Display of the dnExtMaster_p
input signal in the real unit of the
machine.
Parameter Possible settings Info