5.113 L_PosProfileTable - profile data record management (simple)
424
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.113.1 Profile data table
Profile parameter data is directly entered under the assigned codes.
Exception: The position assigned to the input dnExtPos_p will be used as target position if pro-
file number 1 is selected.
Conversion of the values into internal values
The profile parameters are always entered in the application unit [unit].
•Since the SBLS_Positioner needs the profile parameters in the internal measuring system, the
FB L_PosProfileTable also stores the values in this measuring system.
The values must only be reconverted by the FB if the machine parameters transmitted by the
drive interface via the input AxisData have changed.
In this case the output bBusy is set to TRUE during the conversion and an access to the profile
parameters is not possible.
Profile parameters Unit Profile no. 1 Profile no. 2 Profile no. 3 Profile no. 4
Positioning mode - C04750/1 C04750/2 C04750/3 C04750/4
Position Unit
dnExtPos_p C04751/2 C04751/3 C04751/4
Speed Unit/t C04752/1 C04752/2 C04752/3 C04752/4
Acceleration Unit/t
2
C04753/1 C04753/2 C04753/3 C04753/4
Delay Unit/t
2
C04754/1 C04754/2 C04754/3 C04754/4
S-ramp time s C04755/1 C04755/2 C04755/3 C04755/4
TP sequence profile - C04756/1 C04756/2 C04756/3 C04756/4
TP selection - C04757/1 C04757/2 C04757/3 C04757/4
Note!
The values to be "taught" are exceptions. They must be selected in the internal measu-
ring system.