User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 571
5 Function blocks
5.164 L_TbCurveAny - Characteristic function
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tip!
For a better understanding, in the following examples, the converted percentages referring
to the limit values 2
31
-1 and -(2
31
) are entered instead of the real DINT values.
5.164.1 Selection of the characteristic
The up to 127 points of the characteristic are selected via the subcodes of C04046 and C04047.
The same subcodes of C04046 and C04047 correspond to a pair of variates/point (x
n
, y
n
).
The first pair of variates (C04046/1 and C04047/1) is always valid.
• The x values of the characteristic must be entered in ascending order (x1<x2<…<x127).
If the ascending chain of x values is interrupted, this corresponds to the end of the characteristic
(in the example X5 < X4):
Based on the last valid pair of variates, an extrapolation is executed to the end of the x value
range (2
31
)-1 on both sides.
In the characteristic modes 1 and 2, only the range of the characteristic entered in the quadrants
I. and IV. is used.
C04046/1...127 -2147483648 2147483647 X values of the characteristic func-
tion
Subcodes 1 ... 127 correspond to
the point values X1 ... X127.
•Initialisation: 0
C04047/1...127 -2147483648 2147483647 Y values of the characteristic func-
tion
Subcodes 1 ... 127 correspond to
the point values Y1 ... Y127.
•Initialisation: 0
Parameter Possible settings Info
1 2 ... 127
x C04046/1 C04046/2 C04046/... C04046/127
Y C04047/1 C04047/2 C04047/... C04047/127
1 2 3 4 5 6 ... 126 127
x
-140 % -90 % 70 % 145 % 00000
y
-140 % -40 % 115 % 160 % 0 0 0 0 0