User guide

3 Working with the FB editor
3.4 Creating/reconfiguring the interconnection
90
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.4.11.1 Insert options for copied elements
If interconnection elements have been copied to the clipboard, the »Engineer« displays a list of all
elements contained in the clipboard after the Insert command has been inserted in the Add copied
elements to the function block interconnection dialog box:
The list shows the elements which can be added to the target interconnection without any further
action, and the elements with problems and those which cannot be added.
Each element only appears once in the list even if there are several problems.
If there is at least one name conflict, there are three options of how to solve name conflicts. If
the option is changed, the list is updated accordingly.
The first column "Copied element" serves to define which elements are to be inserted by set-
ting/resetting checkmarks.
In the default setting, all elements to be inserted are always selected.
When you deselect the All option, all elements in the list are deselected.
•The Reverse selection button serves to reverse the existing selection.
The second column "Problem" shows the currently existing problems.
The third column "To be added" contains changes for conflicts with already available elements
in the target interconnection to be able to accept the elements. The automatic suggestions de-
pend on the selected option how to solve name conflicts.