Manual
26
EDK94PNE36 DE/EN/FR/ES/IT 3.1
Overview
Standard device
Pos. Description
X11 24 V supply
X12
4 digital outputs
1 digital input
Nameplate, retractable
Setting of mains voltage/brake chopper threshold
Upper cap
The LED display enables fast indication of several operating states.
LED Labelling Colour Description
− − −
OVERHEAT Red Overtemperature
MAINS Green Mains voltage OK
BRCHOP FAIL Red Short circuit on brake chopper
24 V Green 24 V supply voltage OK
SSP94LED21
BRCHOP ON Yellow Brake chopper active
Pos. Symbol Description
Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!
High discharge current: Fixed installation and PE connection to EN 61800−5−1
required!
Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!
Installation backplane
Pos. Description
X111
Mains (supply from above, e.g. from top filters)
DC−bus voltage (compatible with 9300 series)
X112
Mains (supply from below, e.g. from built−on filter)
External brake resistor
X109 DC−bus busbar +
Direct connection of
9400 axis modules,
device sizes 1 ... 3
X110 DC busbar −
EMC shield clamp
© 2009 Lenze Automation GmbH, Hans−Lenze−Str. 1, D−31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Automa-
tion GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur. Ne-