Manual
Wiring of the standard device 7
45
EDK94PNE36 DE/EN/FR/ES/IT 3.1
24 V supply
Terminal X11 Labelling Description
GE GND external supply
SSP9400X11
24E 24 V external supply through safely separated power supply unit
(SELV/PELV)
IEC 61131−2, 19.2 ... 28.8 V, residual ripple max. ±5 %
Current during operation: 450 mA
Starting current: 4 A for 100 ms
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm
Digital inputs, digital outputs
Terminal X12 Labelling Description
GOI GND digital out/in
DI1 External control of the brake chopper for discharge after power−off
(24−V supply at X11 required)
DO1 Mains OK
DO2 Brake chopper active
DO3 Short circuit in brake chopper
SSP9400X12
DO4 Heatsink overtemperature
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm