User Manual

Wiring of the standard device 6
l
53
EDK94ARN24 DE/EN/FR/ES/IT 2.1
I Tip!
Parameter setting and configuration can be carried out using the
L−force »Engineer«. For this purpose the Online Help and the Software Manual
for the standard device will guide you.
System bus CAN on board
Terminal X1 Labelling Description
Pin 2 CAN−LOW
Pin 3 CAN−GND
Pin 7 CAN−HIGH
9400SSP000X1
(Housing) CAN−Shield
24 V supply
Terminal X2 Labelling Description
GE GND external supply
24E 24 V external supply via a safely separated power supply unit
(SELV/PELV)
9400SSP000X2
SB State bus in/out (reference GE)
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Analog inputs, analog outputs
Terminal X3 Labelling Description
GA GND analog signals
AO1 Analog output 1
AO2 Analog output 2
A1+ Analog input 1 +
A1− Analog input 1 −
A1− Analog input 1 −
A1R Terminating resistor for ±20mA
A2+ Analog input 2 +
A2− Analog input 2 −
SSP94000X3
"
Shield connection: Fix the shield with EMC wire clamp.
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule