9400 Technology applications | Actuator – speed
Parameter setting & configuration
Speed setpoint conditioning
4.3.1 Change-over to fixed setpoint
[4-3] Additional offset for the speed limit value (schematic diagram)
Via the digital input DI4 a change-over to a parameterisable fixed setpoint can take place.
r Parameter setting: Tab Application parameters dialog level Overview
Use of further fixed setpoints
A total of 15 different fixed setpoints can be parameterised. For the selection of the fixed
setpoints 2
... 15 the selection inputs are to be assigned with the corresponding signals.
The selection of the fixed setpoints is carried out in a binary coded manner.
r Parameter setting: Tab Application parameters dialog level Overview Ramp
generator All fixed setpoints
Gain Invert setpointSelection
LS_Speed...
M
Speed
setpoint
DI2DI3DI4
OUT
IN
Ramp generator
%1
%2
%15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Parameter Lenze setting
Value Unit
C03500/1 Fixed setpoint 1 10.00 %
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DIGIN 4 Activate fixed setpoint 1 C03009/4
Parameter Lenze setting
Value Unit
C03500/1 Fixed setpoint 1 10.00 %
C03500/2 Fixed setpoint 2 0.00 %
C03500/... Fixed setpoint ... ... ...
C03500/15 Fixed setpoint 15 0.00 %
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DIGIN 4 Activate fixed setpoint 1 C03009/4
FALSE Activate fixed setpoint 2 a C03009/5
FALSE Activate fixed setpoint 4 a C03009/6
FALSE Activate fixed setpoint 8 a C03009/7