4.12.3 SpeedRamp
Is an instance of Function
L_SdSpeedSet Ramp generator for speed setpoint
Speed setpoint conditioning
(C 18)
Parameter Possible settings Information
C03500/1...15 -200.00 % 200.00 Fixed setpoint 1...15
C03501 015Active setpoint
•Read only
C03502 0.000 s 1000.000 Basic acceleration time
Initialisation: 1.000 s
C03503 0.000 s 1000.000 Basic deceleration time
Initialisation: 1.000 s
C03504 0.000 s 10.000 Basic S-ramp time
Initialisation: 0.100 s
C03507 Polarity of bStop input
0Active HIGH
1Active LOW
C03508 0.00 % 100.00 Setpoint tolerance reached
Initialisation: 1.00 %
C03512/1...15 0.000 s 1000.000 Acceleration time 1...15
Initialisation: 0.000 s
C03513/1...15 0.000 s 1000.000 Deceleration time 1...15
Initialisation: 0.000 s
C03514/1...15 0.000 s 1000.000 S-ramp time 1...15
Initialisation: 0.000 s
C03515 0 15 Active ramp parameters
•Read only
C03520 Profile mode
•Read only
0 Profile generation with linear ramps
Referred to the reference speed
(C00011).
1 Profile generation with jerk
limitation (S-shaped ramps)
10 Profile generation with linear ramps
Referred to the reference speed
(C00011).
At an edge change at the input
bStop referred to the current
setpoint (constant time).
The setpoint applied at the input
dnExtSpeedSetpoint_n is used as
the start value.
C03521 -200.00 % 200.00 Setpoint at the input
•Read only
C03522 -200.00 % 200.00 Target setpoint
•Read only
C03523 -200.00 % 200.00 Setpoint at the output
•Read only