User guide

2 Technical data
Rated data
EDKE94AZHB DE/EN/FR/ES/IT 1.0
34
H1_Daten−Bemessdat_DIO_E94AZH_AB
Rated data
General electrical data
Area Values
Input voltage DC 24 V (18 ... 30 V)
Output voltage Corresponds to input voltage
Brake current 0.3 ... 5 A
Switching capacity Max. 110 W
Breaking energy Max. 10 Ws
Cable protection Recommendation: 7.5 A, tripping characteristic "B" or "C"
Maximum cable length In the chapter "Electrical installation" the dependency of the cable
length on the brake current and the cable cross−section is described.
Operating frequency Max. 6/min
Operating times Can be ignored compared to the delay time of the brake.
See documentation of the brake.
Service life > 10 millions of cycles
Protection against
Overload No
Short circuit of the
terminals
Yes
Polarity reversal at the
input
Yes
Insulation
1)
Double insulation (EN61800−5−1: V
rated
= 300 V AC),
Separation (UL: V
rated
= 500 V AC)
1)
Brake connection against control card of the controller