User guide

Electrical installation
Connection data
4
EDKE94AZHB DE/EN/FR/ES/IT 1.0
41
H1_E_INST−−−−(DUMMYSEITEVOR)−−−
Connection data
Terminal X107 Labelling Description
Connection of the motor holding brake
BD1
BD2
+ (Lenze: WH)
− (Lenze: BN)
E94AZHx0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / −
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
SSP94X6107
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.5 ... 2.5 20 ... 12 Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm
Terminal X121 Labelling Description
DI Connection for external control
in accordance with IEC 61131−2
GI Reference potential
DO Connection for external feedback
in accordance with IEC 61131−2
SSP940X121
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5 24 ... 12 Spring terminal
With wire end
ferrule