Manual
2 Technical data
Rated data
EDK94AZHY25 DE/EN/FR/ES/IT 2.2
34
H1_Daten−BemDat_Br_E94AZHx0025
Permissible operating frequencies
Recommended brake Power Coil: Voltage DC 205 V Permissible operating
frequency
Type P [W] L [H] I [A] (20 °C) [1/min]
BFK457−06E
BFK458−06E
20
76 0.10 60
BFK457−08E
BFK458−08E
25 66 0.12 60
BFK457−10E
BFK458−10E
30 85 0.15 60
BFK457−12E
BFK458−12E
40 107 0.20 40
BFK457−14E
BFK458−14E
50 102 0.24 30
BFK457−16E
BFK458−16E
55 127 0.27 20
BFK457−18E
BFK458−18E
85 100 0.41 10
BFK457−20E
BFK458−20E
100 115 0.49 8
BFK457−25E
BFK458−25E
110 134 0.54 6